CZ1-01
H Date of birth : 05/1955 / Center : CZ1 - Fakultní Thomayerova nemocnice
|
|
Menu
4 V0 : Implantation Visit (or implantation attempt) - 28/02/2024Implantation
Has the patient been implanted with ARTUS®?
Yes
How many implantation attempts have there been?
Please explain why and describe the difficulty(ies) experienced:
1) Before starting the surgical procedure
The results of the 24-hour Pad Weight Test have been entered in the Baseline visit to validate the inclusion of the subject
Yes
Clinical Examination
Was the clinical examination performed
Yes
Vital sign measurements
Weight
114
kg
Body Mass Index
32.3
kg/cm²
Explain why clinical examination was not performed
2) Preparation for surgical procedure1. Device preparation1.1 Charge of the Remote controls
The charge of the TWO Remote Controls was done correctly before the surgery (for 5 hours each)
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
1.2 Start procedure
All steps for the "Start procedure" of the two Remote Controls have been completed
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
Comments
1.3 Pairing of the Remote Control with Control Unit
All steps for "Pairing procedure" of the Remote Control and the Control Unit have been completed
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
Comments
2. Calibration procedure
All the steps of the 'Calibration procedure' have been completed
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
Comments
2) Implantation procedureAt the end of procedure, material used
LOT of the ARTUS® Cuff S
22-0224
SN of the ARTUS® Control Unit
210011
SN of the ARTUS® Remote Control #1
052300185
SN of the ARTUS® Remote Control #2
Material Back-up
The Back-up Material was used
No
LOT of the ARTUS® Cuff S
SN of the ARTUS® Control Unit
SN of the ARTUS® Remote Control
1. Surgery1.1 Duration of procedure
Beginning of the surgery, start of the incision (hh:mm)
10:00
End of the surgery, closure of the incision (hh:mm)
11:15
1.2 Anesthesia
What type of anesthesia performed ?
General
1.3 Foley catheter insertion
Size of Foley catheter used
14 CH
1.4 DissectionDid a surgical dissection of the bulbospongiosus muscle has been performed?
1.5 Cuff implantation
Locking Position of the cuff around the urethra
1
Tightening of the urethra
If you have encountered difficulties, please describe the difficulty(ies) experienced and alternative or solution provided
no difficulties
Comment
1.6 Surgery test procedure
All steps for the "Surgery Test procedure" have been completed
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
Comments
1.7 Implantation of the Control Unit
All steps for the "Implantation of the control unit" have been completed
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
Comments
1.8 Completion of implantation
All steps for the "Completion of implantation" have been completed
Yes
Describe the difficulty(ies) experienced and alternative or solution provided
Comments
1.9 Pictures of the final position of the Cuff around the urethra
Was a Picture of the Cuff final position around the urethra taken intra-operatively
Yes
1.10 Picture of the final position of the Control Unit
Was a Picture of the Control Unit final position taken intra-operatively
Yes
Pelvis radiography Front and Profil (to ensure proper positioning of the Control Unit implanted)Radiography immediately post-surgical procedure
Was the Pelvis radiography performed?
Yes
Usability Questionnaire Surgeon (Intra-operative)
Was the Usability Questionnaire Surgeon (intra-operative) performed
Yes
Explain why Usability Questionnaire Surgeon was not performed
Artus® implantationConcerning the implantation of the ARTUS device, do you agree with the following affirmations
1. The implantation of Artus® is technically simple
2 : Agree
2. The handling of the shell screwed on the end of the transmission cable is easy
2 : Agree
3. The cuff is easy to insert around the urethra
2 : Agree
4. Positioning the Cuff around the urethra is easy to perform
3 : Not sure
5. The Cuff loop around the urethra is easy to adjust
2 : Agree
6. The implantation technique of the Control Unit in the abdominal wall is easy to perform
2 : Agree
7. The fixing technique for the Control Unit in the abdominal wall is easy to perform
2 : Agree
8. The connection of the transmission cable and the Control Unit is easy to perform
2 : Agree
Using the remote control in operative periodConcerning the intraoperative use of the remote control, do you agree with the following affirmations
9. The remote control is easy to manipulate in the sterile bag
2 : Agree
10. The sequence to be carried out to reach the screen proposing the password to access the Physician interface is simple
2 : Agree
11. Matching between the Remote Control and the implanted Control Unit is easy to perform
2 : Agree
12. Visual evaluation of the correct operation of the device (Surgery mode) is easy to perform
2 : Agree
Do you have any comments regarding the intra-operative ARTUS implant and its use
No
Please complete your comment below
Device deficiency
Device deficiency(ies) occurred during the procedure
No
Concomitant medications
Is the subject receiving any concomitant medication
Yes
Adverse events
Did new adverse event(s) occur since the informed consent signature
No
2024-03-05 19:55:53 : Created HanaFiserova Fiserová Hana
2024-03-06 21:06:19 : Modified HanaFiserova Fiserová Hana 2024-03-11 19:15:19 : Modified HanaFiserova Fiserová Hana 2024-03-11 19:17:01 : Modified HanaFiserova Fiserová Hana 2024-03-13 19:10:09 : Modified HanaFiserova Fiserová Hana 2024-03-21 14:38:35 : Modified HanaFiserova Fiserová Hana 2024-07-30 11:18:30 : Modified/ Signed HanaFiserova Fiserová Hana 2024-07-30 12:30:18 : Modified/ Accepted vbuzalka Buzalka Vladimir |
||||